From Wikipedia, the free encyclopedia
(Redirected from Catheterization)

Catheter
Catheter disassembled

In medicine, a catheter (/ˈkæθətər/) [1] is a thin tube made from medical grade materials serving a broad range of functions. Catheters are medical devices that can be inserted in the body to treat diseases or perform a surgical procedure. Catheters are manufactured for specific applications, such as cardiovascular, urological, gastrointestinal, neurovascular and ophthalmic procedures. The process of inserting a catheter is called catheterization.

In most uses, a catheter is a thin, flexible tube (soft catheter) though catheters are available in varying levels of stiffness depending on the application. A catheter left inside the body, either temporarily or permanently, may be referred to as an "indwelling catheter" (for example, a peripherally inserted central catheter). A permanently inserted catheter may be referred to as a "permcath" (originally a trademark).

Catheters can be inserted into a body cavity, duct, or vessel, brain, skin or adipose tissue. Functionally, they allow drainage, administration of fluids or gases, access by surgical instruments, and also perform a wide variety of other tasks depending on the type of catheter. [2] Special types of catheters, also called probes, are used in preclinical or clinical research for sampling of lipophilic and hydrophilic compounds, [3] protein-bound and unbound drugs, [4] [5] neurotransmitters, peptides and proteins, antibodies, [6] [7] [8] nanoparticles and nanocarriers, enzymes and vesicles.

Etymology

"Catheter" (from Greek καθετήρ kathetḗr) comes from the Greek verb καθίεμαι kathíemai, meaning "to thrust into" or "to send down" because the catheter allowed fluid to be "sent down" from the body. [9]

Uses

Single-use urinary catheter, 40 cm

Placement of a catheter into a particular part of the body may allow:

History

Ancient inventors

Catheters from the Roman Empire, 1st century AD

Ancient Chinese used onion stalks, the Romans, Hindus, and Greeks used tubes of wood or precious metals. [11]

The ancient Syrians created catheters from reeds.

Modern

The earliest invention of the flexible catheter was during the 18th century. [12] Extending his inventiveness to his family's medical problems, Benjamin Franklin invented the flexible catheter in 1752 when his brother John suffered from bladder stones. Franklin's catheter was made of metal with segments hinged together with a wire enclosed to provide rigidity during insertion. [13] [14]

According to a footnote in his letter in Volume 4 of the Papers of Benjamin Franklin (1959), Franklin credits Francesco Roncelli-Pardino from 1720 as the inventor of a flexible catheter. In fact, Franklin claims the flexible catheter may have been designed even earlier. [15]

An early modern application of the catheter was employed by Claude Bernard for the purpose of cardiac catheterization in 1844. The procedure involved entering a horse's ventricles via the jugular vein and carotid artery. [16]

In 1929, Werner Forssman first performed central venous catheterization, [17] work which led to the development of cardiac catherization as a treatment, for which he, André F. Cournand and Dickinson W. Richards would win the Nobel Prize for Medicine in 1959. [18] Central venous catheterization allows for continuous administration of medications, fluids and blood products to a large vein, particularly in critically ill patients. [17] Cardiac catheterization is the insertion of a catheter into one of the chambers of the heart, which is used for imaging, diagnosis, and the placement of devices such as stents. [19]

David S. Sheridan invented the modern disposable catheter in the 1940s. [20] Prior to this, some reusable catheters consisted of braided cotton tubes, which were varnished, heat-treated and polished. As these were primarily produced in France, the advent of World War II threatened the supply chain. [21] Sheridan was dubbed the "Catheter King" by Forbes magazine in 1988. He also invented the modern "disposable" plastic endotracheal tube now used routinely in surgery. [20]

Other reusable catheters consisted of red rubber tubes. Although sterilized prior to reuse, they still posed a high risk of infection and often led to the spread of disease. [22]: 142 

To prevent clotting, catheters that are not in use may be filled with catheter lock solution. [23]

Materials

Urinary catheters

A range of polymers are used for the construction of catheters, including silicone rubber, nylon, polyurethane, polyethylene terephthalate (PET), latex, and thermoplastic elastomers. Silicone is one of the most common implantable choice because it is inert and unreactive to body fluids and a range of medical fluids with which it might come into contact. On the other hand, the polymer is weak mechanically, and a number of serious fractures have occurred in catheters. [24] [25] [26] For example, silicone is used in Foley catheters where fractures have been reported, often requiring surgery to remove the tip left in the bladder.

There are many different types of catheters for bladder problems. A typical modern intermittent catheter is made from polyurethane and comes in different lengths and sizes for men, women and children.[ citation needed]

Catheters used in interventional procedures

Depending on the mechanical characteristics required, assorted polymers and polymer-metal composites can be used to build catheters used for interventional purposes. Common materials include polyamide (nylon), polyether block amide, polyuerathane, polyethylene terephthalate, and polyimides. These materials are often used in combination with each other and are frequently layered on top of stainless steel braiding, laser-cut stainless steel tubing, or other scaffold-like structures to impart desirable handling characteristics to the catheter, all dependent on the intended application. For example, the materials and the architectures used to manufacture vascular catheters for neurological applications might differ significantly from catheters destined for cardiovascular use.

Guiding catheters (catheters that guides angioplasty balloons and stents) is made up of polytetrafluoroethylene (PTFE) innermost layer which is lubricious, followed by stainless steel braid wire outer layer which helps to provide support for the catheter and prevent kinking while travelling through blood vessels, and Nylon elastomer outermost layer which provides extra support for the catheter and preserve the curvature of the catheter while passing through tortuous vessels. [27]

To enhance ease of insertion, some catheters have a lubricious surface coating to lessen friction. A lubricious coating creates a smooth, slippery film making the catheter easier to insert.

Interventional procedures

Various settings of a 6 French pigtail catheter with locking string, obturator (also called stiffening cannula) and puncture needle.
A. Overview.
B. Both puncture needle and obturator engaged, allowing for direct insertion.
C. Puncture needle retracted. Obturator engaged. Used for example in steady advancement of the catheter on a guidewire.
D. Both obturator and puncture needle retracted, when the catheter is in place.
E. Locking string is pulled (bottom center) and then wrapped and attached to the superficial end of the catheter.

Diagnostic catheters

There are various catheters used in angiography procedures. Diagnostic catheters [27] [28] direct wires through blood vessels. Radiocontrast agent is then injected through the catheter to visualise the vessels via various imaging methods such as computed tomography (CT), projectional radiography, and fluoroscopy. [28] Pigtail catheter is a non-selective catheter with multiple side holes that can deliver large volumes of contrast into a blood vessel for imaging purposes. [29] Cobra catheter is a selective catheter used to catheterise downgoing vessels in the abdomen. Cobra catheters move forward by pushing and are removed by pulling. [30] Sidewinder catheter is a selective catheter is used to navigate the aorta. [29] Headhunter, Newton, Simmons, Bentson, and Berenstein catheters are used to navigate the into one of the three branches of the arch of aorta. [31] Yashiro Catheter is a selective, hydrophilic catheter designed for optimal entry into celiac trunk. [32] Whereas endothelial cell sampling through endovascular sampling with coils, stents, stent retrievers, or guidewires suffer from poor selectivity and a low or highly variable cell yield, a micro-3D-printed device adapted for endovascular techniques can harvest endothelial cells for transcriptomic analysis. [33]

Balloon catheters

There are also balloon catheters used in angioplasty procedures such as plain balloon catheters that is useful in passing tight vessel stenosis, drug coated balloons that contains paclitaxel on the surface to prevent smooth muscle cells proliferation of the vessel walls, thus reducing the likehood of vessel blockage in the future, high pressure balloons that can open stubborn vessel stenoses in veins and arteriovenous fistula, and cutting balloon angioplasty that contains 3 to 4 small blades on its surface (endotomes) that helps to control the distribution of balloon dilatation more uniformly and cut through resistant stenosis due to fibrous scar tissue. [34]

Dialysis catheters

There is no difference in achieving adequacy of blood flow, period of catheter usage, infection, and thromboembolism risk whether the dialysis catheter has step-tip, split-tip, or symmetrical tip. [35] Palidrome catheter is superior to Permcath catheter in terms of maximum blood flow, dialysis adequacy, and annual patency rate. Similar to Permcath, Palidrome catheter has high infection and thromboembolism rate. [36]

Adverse effects

In interventional procedures, Teflon catheters (which are hydrophobic) have higher risk of thrombus formation when compared to polyurethene catheters. The longer the duration of the catheter left inside the body, the higher the risk of thrombus formation. Larger catheters increase the risk of thrombus formation around the catheter, because they can block the flow of blood. [37]

"Any foreign object in the body carries an infection risk, and a catheter can serve as a superhighway for bacteria to enter the bloodstream or body", according to Milisa Manojlovich, a professor at the University of Michigan School of Nursing. [38]

Catheters can be difficult to clean, and therefore harbor antibiotic resistant [39] or otherwise pathogenic bacteria.

See also

References

  1. ^ "catheter noun - Definition, pictures, pronunciation and usage notes | Oxford Advanced Learner's Dictionary at". Oxfordlearnersdictionaries.com. Retrieved May 6, 2022.
  2. ^ Diggery, Robert (2012). Catheters: Types, applications and potential complications (medical devices and equipment. Nova Science. ISBN  978-1621006305.
  3. ^ Altendorfer-Kroath, Thomas; Schimek, Denise; Eberl, Anita; Rauter, Günther; Ratzer, Maria; Raml, Reingard; Sinner, Frank; Birngruber, Thomas (January 2019). "Comparison of cerebral Open Flow Microperfusion and Microdialysis when sampling small lipophilic and small hydrophilic substances". Journal of Neuroscience Methods. 311: 394–401. doi: 10.1016/j.jneumeth.2018.09.024. ISSN  0165-0270. PMID  30266621. S2CID  52883354.
  4. ^ Schaupp, L.; Ellmerer, M.; Brunner, G. A.; Wutte, A.; Sendlhofer, G.; Trajanoski, Z.; Skrabal, F.; Pieber, T. R.; Wach, P. (February 1, 1999). "Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion". American Journal of Physiology. Endocrinology and Metabolism. 276 (2): E401–E408. doi: 10.1152/ajpendo.1999.276.2.e401. ISSN  0193-1849. PMID  9950802.
  5. ^ Ellmerer, Martin; Schaupp, Lukas; Brunner, Gernot A.; Sendlhofer, Gerald; Wutte, Andrea; Wach, Paul; Pieber, Thomas R. (February 1, 2000). "Measurement of interstitial albumin in human skeletal muscle and adipose tissue by open-flow microperfusion". American Journal of Physiology. Endocrinology and Metabolism. 278 (2): E352–E356. doi: 10.1152/ajpendo.2000.278.2.e352. ISSN  0193-1849. PMID  10662720. S2CID  11616153.
  6. ^ Dragatin, Christian; Polus, Florine; Bodenlenz, Manfred; Calonder, Claudio; Aigner, Birgit; Tiffner, Katrin Irene; Mader, Julia Katharina; Ratzer, Maria; Woessner, Ralph; Pieber, Thomas Rudolf; Cheng, Yi (November 23, 2015). "Secukinumab distributes into dermal interstitial fluid of psoriasis patients as demonstrated by open flow microperfusion". Experimental Dermatology. 25 (2): 157–159. doi: 10.1111/exd.12863. ISSN  0906-6705. PMID  26439798. S2CID  34556907.
  7. ^ Kolbinger, Frank; Loesche, Christian; Valentin, Marie-Anne; Jiang, Xiaoyu; Cheng, Yi; Jarvis, Philip; Peters, Thomas; Calonder, Claudio; Bruin, Gerard; Polus, Florine; Aigner, Birgit (March 2017). "β-Defensin 2 is a responsive biomarker of IL-17A–driven skin pathology in patients with psoriasis". Journal of Allergy and Clinical Immunology. 139 (3): 923–932.e8. doi: 10.1016/j.jaci.2016.06.038. ISSN  0091-6749. PMID  27502297. S2CID  30272491.
  8. ^ Kleinert, Maximilian; Kotzbeck, Petra; Altendorfer-Kroath, Thomas; Birngruber, Thomas; Tschöp, Matthias H.; Clemmensen, Christoffer (December 2019). "Corrigendum to "Time-resolved hypothalamic open flow micro-perfusion reveals normal leptin transport across the blood–brain barrier in leptin resistant mice" [Molecular Metabolism 13 (2018) 77–82]". Molecular Metabolism. 30: 265. doi: 10.1016/j.molmet.2019.11.001. ISSN  2212-8778. PMC  6889745. PMID  31767178.
  9. ^ Feneley, Roger C. L.; Hopley, Ian B.; Wells, Peter N. T. (November 17, 2015). "Urinary catheters: history, current status, adverse events and research agenda". Journal of Medical Engineering & Technology. 39 (8): 459–470. doi: 10.3109/03091902.2015.1085600. PMC  4673556. PMID  26383168.
  10. ^ "MedlinePlus: Urinary catheters". U.S. National Library of Medicine. November 6, 2019.
  11. ^ "MedTech Memoirs: Catheters". Advantage Business Media. June 16, 2015. Archived from the original on October 24, 2017.
  12. ^ "Didusch Site - Milestones - Relief in a Tube: Catheters Remain a Steadfast Treatment for Urinary Disorders". www.urologichistory.museum. Archived from the original on January 17, 2015.
  13. ^ "Benjamin Franklin: In Search of a Better World". Minnesota Historical Society. Archived from the original on August 12, 2011.
  14. ^ Hirschmann, J.V. (December 2005). "Benjamin Franklin and Medicine". Annals of Internal Medicine. 143 (11): 830–4. doi: 10.7326/0003-4819-143-11-200512060-00012. PMID  16330795. S2CID  32882591. Archived from the original (PDF) on December 17, 2019. Retrieved January 2, 2013.
  15. ^ Huth, E.J. (2007). "Benjamin Franklin's place in the history of medicine" (PDF). Journal of the Royal College of Physicians of Edinburgh. 37 (4): 373–8. PMID  18447203.
  16. ^ Baim, Donald (2005). Grossman's Cardiac Catheterization, Angiography, and Intervention. Lippincott Williams & Wilkins. ISBN  978-0781755672.
  17. ^ a b Smith, Reston N.; Nolan, Jerry P. (November 11, 2013). "Central venous catheters". BMJ. 347: f6570. doi: 10.1136/bmj.f6570. ISSN  1756-1833. PMID  24217269. S2CID  16939469.
  18. ^ "The Nobel Prize in Physiology or Medicine 1956". NobelPrize.org. Retrieved July 16, 2023.
  19. ^ Manda, Yugandhar R.; Baradhi, Krishna M. (2023), "Cardiac Catheterization Risks and Complications", StatPearls, Treasure Island (FL): StatPearls Publishing, PMID  30285356, retrieved July 16, 2023
  20. ^ a b "David S. Sheridan". Washington Post. May 7, 2004.
  21. ^ "David Sheridan, 95; Dropout Invented Key Medical Device". Los Angeles Times. May 4, 2004.
  22. ^ Engineers, NPCS Board of Consultants & (January 1, 2014). Handbook on Medical and Surgical Disposable Products. Niir Project Consultancy Services. ISBN  9789381039281 – via Google Books.
  23. ^ Vanholder, R.; Canaud, B.; Fluck, R.; Jadoul, M.; Labriola, L.; Marti-Monros, A.; Tordoir, J.; Van Biesen, W. (2010). "Diagnosis, prevention and treatment of haemodialysis catheter-related bloodstream infections (CRBSI): a position statement of European Renal Best Practice (ERBP)". NDT Plus. 3 (3): 234–246. doi: 10.1093/ndtplus/sfq041. PMC  6371390. PMID  30792802.
  24. ^ McKenzie, J. M.; Flahiff, C. M.; Nelson, C. L. (October 1, 1993). "Retention and strength of silicone-rubber catheters. A report of five cases of retention and analysis of catheter strength". J Bone Joint Surg Am. 75 (10): 1505–1507. doi: 10.2106/00004623-199310000-00011. ISSN  0021-9355. PMID  8408139. Archived from the original on September 23, 2016. Retrieved May 12, 2016.
  25. ^ Agarwal, Shaleen; Gandhi, Mamatha; Kashyap, Randeep; Liebman, Scott (March 1, 2011). "Spontaneous Rupture of a Silicone Peritoneal Dialysis Catheter Presenting Outflow Failure and Peritonitis". Peritoneal Dialysis International. 31 (2): 204–206. doi: 10.3747/pdi.2010.00123 (inactive January 31, 2024). ISSN  0896-8608. PMID  21427251. Archived from the original on May 8, 2018.{{ cite journal}}: CS1 maint: DOI inactive as of January 2024 ( link)
  26. ^ Mirza, Bilal; Saleem, Muhammad; Sheikh, Afzal (August 14, 2010). "Broken Piece of Silicone Suction Catheter in Upper Alimentary Tract of a Neonate". APSP Journal of Case Reports. 1 (1): 8. ISSN  2218-8185. PMC  3417984. PMID  22953251.
  27. ^ a b Ali, Ronan; Lecturer in Adult Internal Medicine, Faculty of Medical Sciences, University of the West Indies, St Augustine, Trinidad; Greenbaum, Adam B; Director, Cardiac Catheterization Laboratory, Henry Ford Hospital, Detroit, Michigan, US; Kugelmass, Aaron D; Chief of Cardiology and Medical Director, Heart and Vascular Program, Baystate Medical Center, 759 Chestnut Street, Springfield, Massachusetts, US. E: aaron.kugelmassmd@bhs.org (2012). "A Review of Available Angioplasty Guiding Catheters, Wires and Balloons – Making the Right Choice". Interventional Cardiology Review. 7 (2): 100. doi: 10.15420/icr.2012.7.2.100. ISSN  1756-1477.{{ cite journal}}: CS1 maint: multiple names: authors list ( link) CS1 maint: numeric names: authors list ( link)
  28. ^ a b Themes, U. F. O. (June 20, 2016). "Catheter-Based Technology and Devices". Thoracic Key. Retrieved August 15, 2021.
  29. ^ a b Davies, AH; Brophy, CM (October 10, 2005). Vascular surgery. Springer Science & Business Media. p. 239. ISBN  9781852332884. Retrieved February 3, 2022.
  30. ^ Bakal, CW; Flacke, S (December 23, 2015). "Diagnostic Catheters and Guidewires". Radiology Key. Archived from the original on February 3, 2022. Retrieved February 3, 2022.
  31. ^ "Angiography peripheral intervention" (PDF). Merit Medical. p. 21. Archived from the original (PDF) on April 14, 2021. Retrieved February 4, 2022.
  32. ^ Golowa, Yosef S.; Kalva, Sanjeeva P.; D'Othee, Bertrand Janne (April 2009). "Use of a Yashiro Catheter to Facilitate Complex Visceral Catheterization". Journal of Vascular and Interventional Radiology. 20 (4): 557–559. doi: 10.1016/j.jvir.2009.01.014. PMID  19243973.
  33. ^ Sandell, Mikael; Chireh, Arvin; Spyrou, Argyris; Grankvist, Rikard; Al-Saadi, Jonathan; Jonsson, Stefan; van der Wijngaart, Wouter; Stemme, Göran; Holmin, Staffan; Roxhed, Niclas (August 21, 2022). "Endovascular Device for Endothelial Cell Sampling". Advanced NanoBiomed Research. 2 (10): 2200023. doi: 10.1002/anbr.202200023. eISSN  2699-9307. ISSN  2699-9307. S2CID  251730092.
  34. ^ Watson N, Jones H (2018). Chapman and Nakielny's Guide to Radiological Procedures. Elsevier. p. 231. ISBN  9780702071669.
  35. ^ Ling XC, Lu HP, Loh EW, Lin YK, Li YS, Lin CH, Ko YC, Wu MY, Lin YF, Tam KW (April 2019). "A systematic review and meta-analysis of the comparison of performance among step-tip, split-tip, and symmetrical-tip hemodialysis catheters". Journal of Vascular Surgery. 69 (4): 1282–1292. doi: 10.1016/j.jvs.2018.09.029. PMID  30905366. S2CID  85497739.
  36. ^ Li M, Zhang Z, Yu Y, Chen H, Li X, Ma J, Dong Z (March 2014). "Clinical application of long-term Palindrome catheter in hemodialysis patients". Iranian Journal of Kidney Diseases. 8 (2): 123–9. PMID  24685735.
  37. ^ Formanek, Gustave; Frech, Robert S.; Amplatz, Kurt (May 1970). "Arterial Thrombus Formation During Clinical Percutaneous Catheterization". Circulation. 41 (5): 833–839. doi: 10.1161/01.CIR.41.5.833. ISSN  0009-7322.
  38. ^ Laura Bailey (July 1, 2019). "Catheters: Big source of infection, but often overlooked". University of Michigan. Retrieved February 16, 2020.
  39. ^ "Nobody wants to talk about catheters. Our silence could prove fatal | Mosaic". Mosaicscience.com. November 7, 2018. Retrieved November 13, 2019.

External links